What was found
AFT PASSENGER COMPARTMENT FLOOR STRUCTURE - WET AREA; FLOOR BEAM STA 986.5; RB2 45; FOUND CORROSION AROUND FASTENER HOLE.<[01] REMOVED NUTPLATE AT CABIN PASSENGER FLOOR STRUCTURE- WET AREA FLOOR BEAM STA 986.5; RBL 45 AS PER SRM 51-40-02-0G-0;[02] REMOVED CORROSION AT CABIN PASSENGER FLOOR STRUCTURE- WET AREA FLOOR BEAM STA 986.5; RBL 45 AS PER SRM 51-10-02-0G-0;[17] FABRICATED REPAIR PARTS. STRAP; ANGLE AND FILLER AS PER SRM 53-70-51-2R-6 TABLE 204;[18] VERIFIED STEP 17. VERIFIED FABRICATION OF REPAIR PARTS.;[19] TREATED AND PRIMED REPAIR PARTS AND BARE METAL OF THE REPAIR AREA AS PER AMM 51-21-41-370-801 AND AMM 51-21-72-370-804;[20] REINSTALLED NUTPLATE REMOVED IN STEP 1 AS PER SRM 51-40-02-0G-0;[21] VERIFIED STEP 19 AND 20. OK TO INSTALL FABRICATED PARTS.;[22] INSTALLED FABRICATED PARTS AS PER REFERENCE SRM 53-70-51-2R-6; FIGURE 205; ALTERNATIVE 4.;[23] REMOVED CORROSION; EVALUATED REWORKED AREA. ORIGINAL THICKNESS 0.150'; MATERIAL LOST 0.110'; MATERIAL REMAINING 0.040'. FOUND OUT OF LIMITS; FABRICATED; TREATED; PRIMED AND INSTALLED REPAIR PARTS. STRAP; ANGLE AND FILLER AS PER SRM 53-70-51-2R-6 TABLE 204 AND SRM 53-70-51-1A-1;[24] VERIFIED STEPS 22 AND 23 AS FINAL.