What was found
CORROSION ON FLOOR STRUCTURE INTERCOSTAL BRAKE PANEL LOCATED BTW BS 294.5 TO BS 312 AT FWD GALLEY AREA 2023-185239<[01] TOOL USED: ULTRASONIC THICKNESS GAUGE; PN: 45MG; SN: 221861811; DUE DATE: 08-NOV-23;[02] REPLACED NEW INTERCOSTAL BRAKE PANEL LOCATED BTW BS 294.5 TO BS 312 AT FWD GALLEY AREA AND FASTENERS I.A.W B737-700 SRM 51-40-02 AND DWG 141A5400 REV - SHEET 8 SEE INDIVIDUAL SIGN OFF BELOW;[03] RII ITEM <BR>REPLACED NEW INTERCOSTAL BRAKE PANEL LOCATED BTW BS 294.5 TO BS 312 AT FWD GALLEY AREA AND FASTENERS I.A.W B737-700 SRM 51-40-02 AND DWG 141A5400 REV - SHEET 8 SEE INDIVIDUAL SIGN OFF BELOW<BR>TASKCARD COMPLETED