What was found
CRACKED INTERCOSTAL AT BS 312-328 LBL 44 WL 208.<[01] CRACKED INTERCOSTAL FOUND TO BE CRACKED 1.306' LONG AROUND CENTER UPPER FLANGE FASTENER HOLE .040 ORIGINAL THICKNESS OUT OF LIMITS IAW SRM 53-10-51-1A-1 FIG 105 (A) REMOVED CRACKED DAMAGED INTERCOSTAL AT BS 312 TO BS 328 LBL 44 WL 208 IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED NEW INTERCOSTAL IAW SRM 51-40-05-0G-0 OK TO INSTALL;[02] VERIFIED CORRECTIVE ACTION #1.<BR>VERIFIED OK TO INSTALL NEW INTERCOSTAL.;[03] INSTALLED NEW INTERCOSTAL AT BS 312 TO BS 328 LBL 44 WL 208 IAW SRM 51-40-02-0G-0 AND BOEING DWG 141A5400;[04] VERIFIED CORRECTIVE ACTION #3.;[05] UPDATED AND COMPLETED MEASUREMENTS TABLE;[06] VERIFIED MEASUREMENTS.