What was found
FWD CARGO COMPARTMENT LH TRANSITION ANGLE BETWEEN STA 500C-500D HAS CORROSION.(MARKED)<[01] BLENDED AREAS; REMOVED .003' MATERIAL; FOUND TO BE WITHIN LIMITS PER SRM 53-00-53-1A-2;[02] VERIFIED ROBERT DENSFORD (TECHNICIAN); 30-MAY-2023 15:13 UTC<BR>BLENDED AREAS; REMOVED .003' MATERIAL; FOUND TO BE WITHIN LIMITS PER SRM 53-00-53-1A-2;[03] BLENDED AREAS; REMOVED .003' MATERIAL; FOUND TO BE WITHIN LIMITS PER SRM 53-00-53-1A-2. TREATED AND PRIMED PER SRM 51-20-01.;[04] VERIFIED CORROSION REMOVAL ROBERT DENSFORD (TECHNICIAN); 30-MAY-2023 17:34 UTC BLENDED AREAS; REMOVED .003' MATERIAL; FOUND TO BE WITHIN LIMITS PER SRM 53-00-53-1A-2. TREATED AND PRIMED PER SRM 51-20-01.;[05] VERIFIED CORROSION REMOVAL ROBERT DENSFORD (TECHNICIAN); 30-MAY-2023 17:34 UTC BLENDED AREAS; REMOVED .003' MATERIAL; FOUND TO BE WITHIN LIMITS PER SRM 53-00-53-1A-2. TREATED AND PRIMED PER SRM 51-20-01.