What was found
ON CLIMBOUT AND AFTER THE FLAP HANDLE WAS IN THE UP POSITION; THE FLAP INDICATOR SHOWED FLAPS STILL AT 5. AND WE COULD SEE OUT THE WINDOW THAT THE LEADING EDGE DEVICES WERE EXTENDED<[01] T/S REF FIM 27-51 TASK 801;NO EXISTING FAULTS OR FAULT HISTORY @ FSEU NOTED.PERFORMED DVI OF ALL T.E. FLAP ACTUATORS & DRIVE COMPONENTS.NO DEFECTS NOTED DURING UP & DOWN POSITIONS AND TRANSIT CONDITIONS.R&R FSEU REF AMM 27-51-01;R&R T.E. FLAP INDICATOR REF AMM 27-58-02.NO FURTHJER ACTION REQ?D.