What was found
(CUSTOMER REQUEST) CRACK ANGLE LOCATED BS 663.75 AND RBL 6 AT CENTER SECTION 2023-413205<[01] TOOL USED: ET EQUIPMENT P/N: NORTEC 500D; S/N: N500X12101V022233; DUE DATE: 30-AUG-23;[02] TOOL USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 25-JAN-24.;[03] PERFORMED PERMANENT REPAIR ON VAPOR BARRIER ATTACH ANGLE LOCATED AT BS 663.75 AND BTW RBL 5.00 TO RBL 20 IWA B737-700 SRM 57-10-10-2R-5 REPAIR 5 FIGURE 202 SHEET 4 DETAIL B SEE INDIVIDUAL SIGN OFF BELOW.;[04] CORRECTED STEP 3.<BR>PERFORMED PERMANENT REPAIR ON VAPOR BARRIER ATTACH ANGLE LOCATED AT BS 663.75 AND BTW RBL 5.00 TO RBL 20 IWA B737-700 SRM 57-10-10-2R-5 REPAIR 5 SEE INDIVIDUAL SIGN OFF BELOW.;[05] PERFORMED PERMANENT REPAIR ON VAPOR BARRIER ATTACH ANGLE LOCATED AT BS 663.75 AND BTW RBL 5.00 TO RBL 20 IWA B737-700 SRM 57-10-10-2R-5 REPAIR 5 SEE INDIVIDUAL SIGN OFF BELOW.<BR>RII