What was found
CORROSION ON FLOOR BEAM BS 986.5 AT RBL 54 AND WL 208.1 AFT GALLEY AREA 2023-444058<[01] TOOL USED UT EQUIPMENT P/N: 45MG; S/N: 221860711; CAL DUE DATE: 07-NOV-23;[02] TOOL USED EDDY CURRENT EQUIPMENT PN. NORTEC 600D; SN 220272712; DUE DATE 17-DEC-23;[03] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600D; S/N: 220273012; DUE DATE 17-DEC-23;[04] PERFORMED PERMANENT REPAIR ON FLOOR BEAM BS 986.5 BETWEEN RBL37 TO RBL46 AND WL208.1 AT AFT GALLEY AREA IAW B737-700 SRM 53-70-51-2R-6 REPAIR 6 FIGURE 205 ALTERNATIVE 4.<BR>SEE INDIVIDUAL SING-OFF BELLOW.;[05] CORRECTED ITEM 4 DUE TO TYPE ERROR: PERFORMED PERMANENT REPAIR ON FLOOR BEAM BS 986.5 BETWEEN RBL37 TO RBL46 AND WL208.1 AT AFT GALLEY AREA IAW B737-700 SRM 53-70-51-2R-6 REPAIR 6 FIGURE 205 ALTERNATIVE 4. <BR>SEE INDIVIDUAL SIGN OFF BELLOW.;[06] TASK CARD COMPLETE AND CERTIFIED AS RII. <BR><BR><BR>SEE INDIVIDUAL SIGNOFFS BELOW.