As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFTER LANDING STRONG ACRID ELECTRICAL SMELL IN COCKPIT AND CABIN. LASTED APROX 3 MINUTES AND DISSIPATED A/C WAS SWITCHED TO APU POWER AND BLEED WHEN SMELL OCCURRED.<[01] INSPECTED AIRCRAFT IAW M/ 05-51-56 FOUND LT RECIRCULATION FAN INTERMITTENT WITH SMELL ; R&R'D LT RECIRC FAN OP'S CK GOOD IAW M/M 21-25-02 NO OTHER DEFECTS NOTED.