What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED STA344 TO STA360 AND BL0 WL208.1 FWD GALLEY AND LAV 2023-490514<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED STA344 TO STA360 AND BL0 WL208.1 FWD GALLEY AND LAV IAW B737-700 SRM-51-40-02 AND DWG-141A5400 REV: - SEE INDIVIDUAL SIGN-OFF BELOW;[02] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED STA344 TO STA360 AND BL0 WL208.1 FWD GALLEY AND LAV IAW B737-700 SRM-51-40-02 AND DWG-141A5400 REV: - SEE INDIVIDUAL SIGN-OFF BELOW RII CERTIFIED