What was found
CRACK ON INTERCOSTAL WEB FLOOR STRUCTURE LOCATED BTW BS 277 TO BS 294.5 LBL 30 AT FWD GALLEY AREA 2023-530688<[01] REPLACED INTERCOSTAL WEB FLOOR STRUCTURE LOCATED BTW BS 277 TO BS 294.5 LBL 30 AT FWD GALLEY AREA IAW SRM B737-700 51-10-02 ITEM 9 AND DRAWING#141A5400 REV:- SEE INDIVIDUAL SIGNOFFS BELOW.;[02] CORRECTED STEP 1.<BR>REPLACED INTERCOSTAL WEB FLOOR STRUCTURE LOCATED BTW BS 277 TO BS 294.5 LBL 30 AT FWD GALLEY AREA IAW SRM B737-700 51-10-02 ITEM 9; SRM 51-40-02 AND DRAWING#141A5400 REV:- SEE INDIVIDUAL SIGNOFFS BELOW.;[03] REPLACED INTERCOSTAL WEB FLOOR STRUCTURE LOCATED BTW BS 277 TO BS 294.5 LBL 30 AT FWD GALLEY AREA IAW SRM B737-700 51-10-02 ITEM 9; SRM 51-40-02 AND DRAWING#141A5400 REV:- RII<BR>SEE INDIVIDUAL SIGNOFFS BELOW.