What was found
CRACK ON INSPAR RIB LOCATED STAB STA 111.10 AND 28 INCHES OF FRONT EDGE AT LT HORIZONTAL 2023-575288<[01] TOOL USED EDDY CURRENT EQUIPMENT P/N: NORTEC 500D; S/N: N500X12101V022237; DUE DATE: 26-JAN-24;[02] TOOL P/N: NORTEC 500D; S/N: N500X1693P030456; CAL DUE: 12-MAR-24.;[03] TOOL P/N: NORTEC 500D; S/N: N500X1693P030456; CAL DUE: 12-MAR-24.;[04] PERFORMED PERMANENT REPAIR LOCATED ON INSPAR RIB LOCATED STAB STA 111.10 AND 28 INCHES OF FRONT EDGE AT LT HORIZONTAL IAW B737-700 SRM 55-10-09-2R-4 REPAIR 4.SEE INDIVIDUAL SIGN OFF BELOW.;[05] PERFORMED PERMANENT REPAIR LOCATED ON INSPAR RIB LOCATED STAB STA 111.10 AND 28 INCHES OF FRONT EDGE AT LT HORIZONTAL IAW B737-700 SRM 55-10-09-2R-4 REPAIR 4.SEE INDIVIDUAL SIGN OFF BELOW.<BR><BR>ITEM RII