What was found
CORROSION ON STR 25L AT BS 360+16 CORRECTION TO FAULT NAME LOCATION SHOULD BE STR 28L AT BS 360+16<[01] CORRECTION TO FAULT NAME CORROSION LOCATION SHOULD READ STR 27L AT BS 360+16;[02] VOID CORRECTIVE ACTION 1 CORRECTION TO FAULT NAME LOCATION SHOULD BE STR 28L AT BS 360+16;[03] REPAIRED STRINGER S28L BS360-BS390<BR>IAW SRM 53-00-03-2R-1 REPAIR 1; AND DWG 143A3230;[04] VERIFIED CORRECTIVE ACTION 3.<BR>VERIFIED MEASUREMENT TABLE.<BR>JOB COMPLETE.