What was found
CRACK ON TIE CLIP LOCATED BS 277 AT LEVEL STR 10R AT FWD GALLEY AREA 2023-661411<[01] REPLACED TIE CLIP AND FASTENERS LOCATED BS 277 AT LEVEL STR 10R AT FWD GALLEY IAW B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02. IAW DWG 141A1110 SHEET 18 REV - SEE INDIVIDUAL SIGNOFFS BELOW.;[02] REPLACED TIE CLIP AND FASTENERS LOCATED BS 277 AT LEVEL STR 10R AT FWD GALLEY IAW B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02. IAW DWG 141A1110 SHEET 18 REV -; RII; SEE INDIVIDUAL SIGNOFFS BELOW.