What was found
CRACK ON ANGLE LOCATED BS 294.5 BTW STR 12L TO STR 14L AT FWD GALLEY AREA 2023-689277<[01] REPLACED ANGLE AND FASTENERS LOCATED ON BS 294.5 BTW STR 12L TO STR 14L AT FWD GALLEY AREA IAW B737 SRM 51-40-02 AND DWG 141A1311; SHEET 1 AND REV: C.;[02] CORRECTED STEP 1: REPLACED ANGLE AND FASTENERS LOCATED ON BS 294.5 BTW STR 12L TO STR 14L AT FWD GALLEY AREA IAW B737 SRM 51-40-02 AND DWG 141A1311; SHEET 1 AND REV: C.<BR>SEE INDIVIDUAL SIGN-OFF BELOW.;[03] CORRECTIVE ACTION STEP 2 CERTIFIED RII