What was found
CRACK FRONT SPAR INSPAR RIB LOCATED STAB STA 120.30 AND 27 INCHES FROM EDGE FRONT SPAR RT HORIZONTAL STAB 2023-748355<[01] TOOL USED ET EQUIPMENT: P/N: NORTEC 600D; S/N: 210138203; CAL DUE DATE: 09-JUN-24;[02] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600D; S/N: 200048001; DUE DATE: 01-MAY-24;[03] PERFORMED PERMANENT REPAIR ON SPAR INSPAR RIB LOCATED STAB STA 120.30 AND 27 INCHES FROM EDGE FRONT SPAR RT HORIZONTAL STAB IAW B737-700 SRM 5T-10-09-2R-5 REPAIR 5 FUGURE 204 SHEET 1 DETAIL A AND IAW B737-700 SRM 5140-02. SEE INDIVIDUAL SIGN OFFS BELOW.;[04] CORRECTED STEP 3<BR>PERFORMED PERMANENT REPAIR ON SPAR INSPAR RIB LOCATED STAB STA 120.30 AND 27 INCHES FROM EDGE FRONT SPAR RT HORIZONTAL STAB IAW B737-700 SRM 55-10-09-2R-5 REPAIR 5 FIGURE 204 SHEET 1 DETAIL A AND IAW B737-700 SRM 51-40-02. SEE INDIVIDUAL SIGN OFFS BELOW.;[05] PERFORMED PERMANENT REPAIR ON SPAR INSPAR RIB LOCATED STAB STA 120.30 AND 27 INCHES FROM EDGE FRONT SPAR RT HORIZONTAL STAB IAW B737-700 SRM 55-10-09-2R-5 REPAIR 5 FIGURE 204 SHEET 1 DETAIL A AND IAW B737-700 SRM 51-40-02. SEE INDIVIDUAL SIGN OFFS BELOW.<BR>CERTIFIED RII