What was found
CRACK ON STRINGER 15L LOCATED AT BS 294.5 MORE 4 INCH AT FWD GALLEY AREA 2023-652267<[01] EQUIPMENT P/N PHASEC 3D; S/N 587435/07; DUE DATE: 15-FEB-24 WAS USED.;[02] REPAIRED STRINGER 15L LOCATED AT BS 294.5 MORE 4 INCH AT FWD GALLEY AREA IAW B737-700 SRM 53-00-03-2R-1 REPAIR 1 STEP 4.K THROUGH L AND TABLE 201 FIGURE 206 SHEETS 1 AND 2;[03] CORRECTED STEP 2: REPAIRED STRINGER 15L LOCATED AT BS 294.5 MORE 4 INCH AT FWD GALLEY AREA IAW B737-700 SRM 53-00-03-2R-1 REPAIR 1 STEP 4.K THROUGH L AND TABLE 201 FIGURE 206 SHEETS 1 AND 2. SEE INDIVIDUAL SIGN-OFFS BELOW.;[04] REPAIRED STRINGER 15L LOCATED AT BS 294.5 MORE 4 INCH AT FWD GALLEY AREA IAW B737-700 SRM 53-00-03-2R-1 REPAIR 1 STEP 4.K THROUGH L AND TABLE 201 FIGURE 206 SHEETS 1 AND 2. SEE INDIVIDUAL SIGN-OFFS BELOW.