What was found
CUSTOMER REQUEST CRACK ON VAPOR BARRIER LOCATED AT MAIN WHEEL WELL LBL<BR> 40 AND WL 168. 2023-758127<[01] TOOL USED; CALIPER PN: 500-197-30; SN: A18135081; DUE DATE: 21-JUL-24.;[02] TOOL USED: HOT BONDER P/N: HCS9200B; S/N: 15102320; DUE DATE: 22-JAN-24.;[03] TOOL USED: SCALE P/N: 91847; S/N: AE-409315; DUE DATE: 08-JUN-24.;[04] TOOL USED SCALE P/N: SPX621; S/N: 8340225491; DUE DATE: 15-AUG-24.;[05] TOOL USED HOT BONDER P/N: HCS9200B S/N: 15102320 DUE DATE: 22-JAN-24.;[06] TOOL USED: ULTRASONIC EQUIPMENT. P/N: GEIT1480179. S/N: GOPLS15100158. DUE DATE: 25-SEP-24.;[07] REPAIRED VAPOR BARRIER LOCATED AT MAIN WHEEL WELL LBL 40 AND WL 168. IAW B737-700 SRM 51-70-04-2R-10 REPAIR 10. SEE INDIVIDUAL SIGNOFFS BELOW.;[08] REPAIRED VAPOR BARRIER LOCATED AT MAIN WHEEL WELL LBL 40 AND WL 168. IAW B737-700 SRM 51-70-04-2R-10 REPAIR 10. SEE INDIVIDUAL SIGNOFFS BELOW. RII ACCOMPLISHED