What was found
CRACK INSPAR RIB LOCATED STAB STA 120.30 AND 20 INCHES FROM FRONT SPAR EDGE AT LT HORIZONTAL STABILIZER 2024-68016<[01] STEP 3 AND 4 EDDY CURRENT EQUIPMENT USED P/N: NORTEC 600D; S/N:210138003; DUE DATE: 27-MAR-24;[02] TOOL USED ON STEP 6 AND STEP 7; EDDY CURRENT EQUIPMENT USED P/N: NORTEC 600D; S/N:210136503; DUE DATE: 23-MAY-24;[03] PERFORMED PERMANENT REPAIR INSPAR RIB LOCATED STAB STA 120.30 AND 20 INCHES FROM FRONT SPAR EDGE AT LT HORIZONTAL IAW B737-700 SRM 55-10-09-2R-5 REPAIR 5.<BR>SEE INDIVIDUAL SIGN OFF BELOW.;[04] PERFORMED PERMANENT REPAIR INSPAR RIB LOCATED STAB STA 120.30 AND 20 INCHES FROM FRONT SPAR EDGE AT LT HORIZONTAL IAW B737-700 SRM 55-10-09-2R-5 REPAIR 5.<BR>SEE INDIVIDUAL SIGN OFF BELOW. <BR>RII CERTIFIED