What was found
R/H WING AFT AILERON CABLE HAS SURFACE CORROSION AT TURN AROUND PULLEY/AILERON QUADRANT FWD OF AILERON INPUT ROD.<[01] FABRICATED TERMINAL B FITTINGS TO NEW CABLES ABSA-R1 AND ABSB-R1 AND CUT CABLE TO LENGTH; PERFORMED PULL-TEST CK. GOOD PER. M.M. 27-09-14 AND SOPM 20-50-16;[02] FABRICATED TERMINAL B FITTINGS TO NEW CABLES ABSA-R1 AND ABSB-R1 AND CUT CABLE TO LENGTH; PERFORMED PULL-TEST CK. GOOD PER. M.M. 27-09-14 AND SOPM 20-50-16;[03] FABRICATED TERMINAL A FITTINGS TO NEW CABLES ABSA-R1 AND ABSB-R1 ; PERFORMED PULL-TEST CK. GOOD PER. M.M. 27-09-14 AND SOPM 20-50-16;[04] INSTALLED RIGHT AILERON CONTROL CABLES ABSA-R1 AND ABSB-R2 PER. M.M. 20-10-91;[05] -DOUBLE TENSIONED NEW CABLE IAW AMM 27-11-00;[06] RII: INSPECTED WORK PERFORMED ON C/A #3; C/A #4; AND C/A #5;[07] ADJUSTED AILERON POGO AND POWER CONTROL UNIT (PCU) PER AMM 27-11-00 DOUBLE TENSIONED RH CABLES CYCLED AILERON 20 TIMES AND ADJUSTED CABLES TO AILERON CABLE RIG LOAD PER AMM 27-09-14 AND AMM 27-11-00 AND MMS AP37.8-0618;[08] RII: VERIFIED CORRECTIVE ACTION #7