What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS 312 TO BS 328 AND LBL 46 FWD GALLEY AND LAV 2024-123170<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 312 TO BS 328 AND LBL 46 FWD GALLEY AND LAV. IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG: 141A5400 SHEET 26 REV SEE INDIVIDUAL SIGN OFFS BELOW.;[02] CORRECT STEP 1: REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 312 TO BS 328 AND LBL 46 FWD GALLEY AND LAV. IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG: 141A5400 SHEET 26 REV - <BR>SEE INDIVIDUAL SIGN OFFS BELOW.;[03] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 312 TO BS 328 AND LBL 46 FWD GALLEY AND LAV. IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG: 141A5400 SHEET 26 REV - <BR>SEE INDIVIDUAL SIGN OFFS BELOW.