What was found
CORROSION ON FWD ENTRY DOOR CUTOUT UPPER SILL WEB LOWER SURFACE BS 308-319 AND BS 334 LBL 41 WL 282.<[01] UPDATED TABLE; COMPLETED STEP 1.;[02] COMPLETED STEPS 2-3;[03] COMPLETED STEP 8;[04] ADDED TO STEP 8;[05] CERTIFIED;[06] STEP 9 COMPLETE;[07] REMOVED CORROSION ON FWD ENTRY DOOR CUTOUT UPPER SILL WEB LOWER SURFACE STA 308-319; LBL 41; WL 282 PER SRM 51-10-02-0G-0. AND MAINTENANCE WAS ACCOMPLISHED ON STEPS 1-9;[08] VERIFIED ALL NECESSARY STEPS ARE COMPLIED WITH; CARD COMPLETE;[09] VERIFIED ALL NECESSARY STEPS ARE COMPLIED WITH; CARD COMPLETE.