What was found
FWD SERVICE DOOR EMERGENCY EXTERIOR SLIDE LIGHT INOP<[01] COMPLETED STEP 1.;[02] MEASUREMENTS;[03] PERFORMED A CONTINUITY CHECK OF WIRES W4142-0011-18 AND 0051-18 FROM CONNECTOR D10748 AND FWD SERVICE DOOR EMERGENCY EXTERIOR SLIDE LIGHT L730 PER WDM 33-51-12 PG2 SH1. NO CONTINUITY FOUND. UPON FURTHER INVESTIGATION FOUND CONNECTOR D11072 DISCONNECTED. RECONNECTED D11072 FOR L730. PERFORMED A GOOD OPS CHECK PER AMM 33-51-00-720-801;[04] UPDATED CORRECTIVE ACTION.;[05] VERIFIED ALL STEPS AND CORRECTIVE ACTION ITEMS; CARD COMPLETE.