What was found
CRACK ANGLE - CLIP LOCATED AFT FACE OF FRAME STA 500A STR 26R FWD CARGO COMPARTMENT 2024-415002<[01] REMOVED ANGLE CLIP LOCATED AFT FACE OF FRAME STA 500A STR 26R FWD CARGO COMPARTMENT AND FASTENERS IAW B737-800 SRM 51-40-02 AND PERFORMED VISUAL INSPECTION ON ADJACENT AREA AND NOT FOUND DAMAGE. TOOK MEASURE OF CRACK IS: 0.875? ON ANGLE - CLIP AFT FACE OF FRAME STA 500A STR 26R FWD CARGO COMPARTMENT; TOOL USED CALIPER P/N: 500-193-30; S/N: 0051667; DUE DATE: 27-AUG-24. EVALUATED CRACK AND NOT FOUND ALLOWABLE DAMAGE IAW B737-800 SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2. ANGLE CLIP MUST BE REPLACED.<BR>REPLACED ANGLE - CLIP LOCATED AFT FACE OF FRAME STA 500A STR 26R FWD CARGO COMPARTMENT I.A.W B737-800 SRM 51-40-02-0G-0 AND DWG: 143A7505; SHEET 109; REV.-.;[02] CERTIFIED WORK PERFORMED.