What was found
CORROSION ON FLOOR SUPPORT STRUCTURE AROUND FITTING BS 947.5; LBL 50<[01] REMOVED DAMAGED ON FLOOR SUPPORT (INTERCOSTAL) AT BS 947.5 LBL 50 WL 208 IN AN AREA OF 1.1' X 1.1'; REMOVED 0.048'; ORIGINAL MATERIAL THICKNESS 0.200'; REMAINING MATERIAL THICKNESS 0.152' FOUND TO BE OUT LIMITS PER SRM 53-70-51-1A-1 ALLOWABLE DAMAGE 1 PAR.4.A(2)(A). PART TO BE REMOVED AND REPLACED PER SRM 51-10-02-0G-0 PAR.9.A(1); TOOL USED ID: ATS2827 DUE: 01/2025. REPLACEMENT OF PART WILL BE ACCOMPLISHED ON CUSTOMER CARD NUMBER TTG8Q00UUSXR STEP 10;[02] VERIFIED CORRECTIVE ACTION COMPLETE.