What was found
FWD CARGO L/H SIDEPLATE HAS CORROSION LBL 24; STA. 500-500A<[01] REMOVED SURFACE CORROSION AT L/H TRANSITION ANGLE FROM STA. 500-500A PER SRM 51-10-02; FOUND TO BE OUT OF LIMITS. MATERIAL REMOVED .010 AND REMAINING THICKNESS .030. PER SRM 53-00-53-1A-2.;[02] VERIFIED CA 1. THINH PHAM (TECHNICIAN); 09-AUG-2024 08:19 UTC<BR>REMOVED SURFACE CORROSION AT L/H TRANSITION ANGLE FROM STA. 500-500A PER SRM 51-10-02; FOUND TO BE OUT OF LIMITS. MATERIAL REMOVED .010 AND REMAINING THICKNESS .030. PER SRM 53-00-53-1A-2.;[03] REPAIRED PER EA M-22-153-01550 AND SRM 53-00-53-2R-5-B00308;[04] REPAIRED PER EA M-22-153-01550 AND SRM 53-00-53-2R-5-B00308;[05] INSPECTED WORK ABOVE;[06] INSPECTED WORK ABOVE