What was found
THE AFT LAVATORY MOUNT STRUCTURE IS CORRODED AT STA 947 RBL 51<[01] REMOVED CORROSION PER SRM 51-10-02. DAMAGE REMOVAL FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1.14] FABRICATED AND DRILLED REPLACEMENT T-CHORD; REPAIR ANGLES; REPAIR STRAPS; FILLERS; AND DRILLED UP NEW REPLACEMENT CLIPS; DEBURRED ALL REPAIR PARTS AND REPAIR AREA IAW SRM 53-70-51-2R-5 ALTERATIVE 1 AND M-24-153-02022 (TTG8Q00V7YUL) AND M-24-153-02031 (TTG8Q00V369S).;[15] STEPS 12 13 & 14 INSPECTED WORK ABOVE;[16] TREATED AND PRIMED REPAIR PARTS AND REPAIR AREA IAW SRM 53-70-51-2R-5 ALTERATIVE 1.;[17] INSPECTED WORK ABOVE STEP 16;[18] RII - OK TO INSTALL STA 947 UPPER T-CAP;[19] REPAIRED DAMAGED FLOOR BEAM UPPER FLANGE PER EA M-24-153-02022; EA M-24-153-02031; AND SRM 53-70-51-2R-5.;[20] INSPECTED AS REQUIRED. CORRECTIVE ACTION #19