What was found
THE AFT LAVATORY MOUNT STRUCTURE IS CORRODED AT STA 947 LBL 50<[01] REMOVED CORROSION PER SRM 51-10-02. DAMAGE REMOVAL IS OUT OF MANUAL LIMITS PER SRM 53-70-51-1A-1. REMAINING THICKNESS IS 0.130?.;[02] RII-C/W INSPECTION AS REQUIRED C/A #1. RICHARD BLACKBURN (TECHNICIAN); 02-AUG-2024 22:37 UTC<BR>REMOVED CORROSION PER SRM 51-10-02. DAMAGE REMOVAL IS OUT OF MANUAL LIMITS PER SRM 53-70-51-1A-1. REMAINING THICKNESS IS 0.130?.;[03] ENTIRE LENGTH OF FLOOR BEAM UPPER FLANGE TO BE REMOVED AND REPAIRED ON FAULT #TTG8Q00UYZC6.;[04] TTG8Q00UYZC6 THE AFT LAVATORY MOUNT STRUCTURE IS CORRODED AT STA 947 RBL 51.;[05] RII INSPECTED AS REQUIRED. CORRECTIVE ACTION #3 AND #4. VERIFIED WORK ACCOMPLISHED ON #TTG8Q00UYZC6