What was found
FWD PASSENGER COMPARTMENT FLOOR STRUCTURE WET AREA; FLOOR BEAM UPPER SURFACE HAS CORROSION AT FLOOR PANEL ATTACH HOLE STA. 328 RBL 39.<[01] REMOVED CORROSION. ORIG THICKNESS OF 0.130IN; REMOVED 0.052IN; REMAINING 0.078IN. FOUND TO BE OUT OF LIMITS PER SRM 53-10-51-1A-1.;[02] TREATED AND PRIMED PER SRM 51-20-01.;[03] C/W INSPECTION AS REQUIRED C/A # 1. MICHAEL PETERSON (TECHNICIAN); 03-AUG-2024 16:29 UTC<BR>REMOVED CORROSION. ORIG THICKNESS OF 0.130IN; REMOVED 0.052IN; REMAINING 0.078IN. FOUND TO BE OUT OF LIMITS PER SRM 53-10-51-1A-1.;[04] COMPLIED WITH EA 24-153-02151 SEE WIP 1; WIP 2 AND SUMMARY FOR ALL STEPS;[05] INSPECTED AS REQUIRED. CORRECTIVE ACTION #4