What was found
CORROSION FOUND ON INTERCOSTAL BETWEEN STA 947 TO STA 967 AT LBL 50.<[01] REMOVED CORROSION PER SRM 51-10-02. DAMAGE REMOVAL IS OUT OF MANUAL LIMITS PER SRM 53-70-51-1A-1. MAX MATERIAL REMOVED 0.030?.;[02] RII- C/W INSPECTION AS REQUIRED C/A #1. RICHARD BLACKBURN (TECHNICIAN); 03-AUG-2024 00:49 UTC<BR>REMOVED CORROSION PER SRM 51-10-02. DAMAGE REMOVAL IS OUT OF MANUAL LIMITS PER SRM 53-70-51-1A-1. MAX MATERIAL REMOVED 0.030?.;[03] RECIEVED NEW PART MATCH DRILLED PER SRM 51-40-02 AND INSTALLED CLICK BOND NUT PLATES PER SRM 51-40-10 AT TIME 1600 AND DATE AUGUST 08 2024.;[04] REQUIRED PULL TEST AND INSTALLATION.;[05] C/W INSP. RECIEVED NEW PART MATCH DRILLED PER SRM 51-40-02 AND INSTALLED CLICK BOND NUT PLATES PER SRM 51-40-10 AT TIME 1600 AND DATE AUGUST 08 2024;[06] INSTALLED NEW REPLACEMENT INTERCOSTAL BETWEEN STA 947 TO STA 967 AT LBL 50 PER SRM 51-40-02. SEE ABOVE CORRECTIVE ACTIONS FOR INDIVIDUAL STEPS;[07] ALL WORK ACCOMPLISHED ON TTG8Q00UYZC6 THE AFT LAVATORY MOUNT STRUCTURE IS CORRODED AT STA 947 RBL 51.;[08] INSPECTED AS REQUIRED. CORRECTIVE ACTION #6 AND #7. VERIFIED WORK ACCOMPLISHED ON FAULT #TTG8Q00UYZC6