What was found
CRACK INDICATION ON STUB FRAME LOCATED BETWEEN BS 294.5 TO BS 296 AND BTW S-8R TO S-9R AT FWD GALLEY DOOR AREA CRACK LENGTH 0.687 IN. APPROX. AT PASSENGER CABIN 2025-80595<[01] INSTALLED STUB FRAME LOC. ON BS 296 BTW S-7R TO S-9R AT FWD GALLEY DOOR AREA IAW B737-700 SRM 51-40-02-0G-0 AND DWG 141A8370 SHEET 9 TO SHEET 11 REV D.;[02] CORRECTED STEP 1. INSTALLED STUB FRAME LOC. ON BS 296 BTW S-7R TO S-9R AT FWD GALLEY DOOR AREA IAW B737-700 SRM 51-40-02-0G-0 AND DWG 141A8370 SHEET 9 TO SHEET 11 REV D. SEE INDIVIDUAL SIGN OFF BELOW.;[03] CORRECTED STEP 1 AND 2. REPLACED STUB FRAME LOC. ON BS 296 BTW S-7R TO S-9R AT FWD GALLEY DOOR AREA IAW B737-700 SRM 51-40-02-0G-0 AND DWG 141A8370 SHEET 9 TO SHEET 11 REV D.