What was found
LEFT 663 VAPOR BARRIER ATTACH ANGLE IS CRACKED AT LBL 35. ] FABRICATED SPLICE ANGLE AND MATCH DRILLED NEW REPLACEMENT ANGLE PER SRM 57-10-10-2R-5. OK TO INSTALL PARTS. PARTS FABRICATION AND OKAY TO INSTALL PER SRM 57-10-10-2R-5C/W INSP. INSTALLED REPAIR FASTENERS COMMON TO FUEL TANK PER SRM 57-10-10-2R-5;[05] 4. INSTALLED REPAIR FASTENERS COMMON TO FUEL TANK PER SRM 57-10-10-2R-5. . INSTALLED L/H 663 UPPER VAPOR BARRIER ATTACH ANGLE REPAIR PER SRM <BR>57-10-10-2R-5. NSTALLED L/H 663 UPPER VAPOR BARRIER ATTACH ANGLE REPAIR PER SRM 57-10-10-2R-5.