What was found
CRACK INSPAR RIB LOCATED STAB STA 120.30 AND 28 INCH FROM FRONT SPAR LT HORIZONTAL STAB 2025-310000<[01] TOOL USED ON STEP 3: EDDY CURRENT EQUIPMENT P/N: NORTEC 600D S:N 220272712 DUE DATE: 28-JAN-26;[02] PERFORMED REPAIR ON INSPAR RIB LOCATED STAB STA 120.30 AND 28 INCH FROM FRONT SPAR LT HORIZONTAL STAB IAW B737-700 SRM 55-10-09-2R-4 REPAIR 4. SEE INDIVIDUAL SIGN OFF BELOW.;[03] TASK COMPLETED; RII <BR><BR>SEE INDIVIDUAL SIGN OFFS BELOW