What was found
LEFT WING TRAILING EDGE - DEFLECTION CONTROL RIB SUPPORT BEAM ATTACHMENT FASTENERS ARE LOOSE AT SERRATED PLATE.<[01] REMOVED INBD AND OUTBD SERRATED PLATES FOR REPLACEMENT IAW SRM 51-40-02.;;[12] INSTALLED TEE FITTING AND UPPER AND LOWER O.B. RADIUS FILLERS PER SRM 57-51-02-2R-3.;[13] QC VERIFIED12. THOMAS BAUER (TECHNICIAN); 13-JUN-2025 00:50 UTC<BR>INSTALLED TEE FITTING AND UPPER AND LOWER O.B. RADIUS FILLERS PER SRM 57-51-02-2R-3.;[14] INSTALLED FASTENERS ON IB SIDE OF T-FITTING ALONG WITH UPPER AND LOWER RADIUS FILLERS IAW SRM57-51-02-2R-3.;[15] INSP VERIFIED WORK SIGNED IN CA#14....... INSTALLED FASTENERS ON IB SIDE OF T-FITTING ALONG WITH UPPER AND LOWER RADIUS FILLERS IAW SRM57-51-02-2R-3......... RII;[16] REPAIRED IAW SRM 57-51-02-2R-3 AND EA 27-157-01569;[17] INSPECTED WORK PERFORMED