What was found
1 CRACK NOTED ON R1 DOOR STUB FRAME, LOCATED 0.7' ABOVE SEAL DEPRESSOR; LENGTH: 2.5'. ENGINEERING TSR REQUIRED. REMOVED AND REPLACED R1 DOOR UPPER STUB FRAME IAW SRM 51-40-02 & DWG 141A8370 REV C, INSTALLED AND ADJUSTED FORWARD UPPER LATCH RECIEVER ON FSD IAW AMM 52-41-00-820-801 (N) (1), AMM 20-50-11-910-801, AND SRM 51-40-02.