What was found
CRACK BRAKE PANEL FLOOR STRUCTURE LOCATED STA540 AND LBL1 AT PASSENGER CABIN. REPLACED FLOORBEAM IAW SRM 51-10-02 ITEM 9 &INSTALLED FASTENERS IAW DRAWING 143A5240 ; SHEET 14; REV - AND SRM 51-40-02.