What was found
BS 663 VAPOR BARRIER ATTACH ANGLE CRACKED ON INBOARD SIDE OF FLEX JOINT @ LBL 9.<[01] REMOVED RIVETS AT L/H STA 663 ATTACH ANGLE COMMON TO VAPOR BARRIER FROM LBL 5 TO LBL 30 PER SRM 51-40-02.;[02] REMOVED CRACKED L ANGLE L/H A/C BAY AFT WALL STA 663 PER SRM 51-00-10.;[03] REJECTION INITIATED ON STEP #3 DUE TO: STEP #1 HAS A ROTABLE COMPONENT REMOVED INSTEAD OF GENERATING A FOUND FAULT FOR THE REMOVAL REQUIREMENT AS MANDATED PER MPM 52.2.1.;;[20] REPLACED L/H BS 663 VAPOR BARRIER LWR ATTACH ANGLE PER SRM 51-40-02 & DWG 111A1000;[21] C/W RII INSPECTION. SEE INDIVIDUAL STEPS FOR WORK ACCOMPLISHED