What was found
CRACK ON ANGLE LOCATED BS 294.5 AT LEVEL STR 13L AT FWD GALLEY AREA. REPLACED ANGLE AND FASTENERS LOCATED BS 294.5 AT LEVEL STR 13L AT FWD GALLEY AREA IAW SRM 51-40-02-0G AND DWG 141A1311 SHEET: 1 REV: C.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON ANGLE LOCATED BS 294.5 AT LEVEL STR 13L AT FWD GALLEY AREA. REPLACED ANGLE AND FASTENERS LOCATED BS 294.5 AT LEVEL STR 13L AT FWD GALLEY AREA IAW SRM 51-40-02-0G AND DWG 141A1311 SHEET: 1 REV: C.