AFT CARGO BAY DOOR SURROUND STRUCTURE (FLOOR) HAS CORROSION ON FLOOR TO SIDEWALL SUPPORT AROUND NUTPLATES; BS 767-794; RBL 22. REMOVED AND REPLACED ACB FWD SHIELD BS767 TO BS794 IAW SRM 51-40-02 AND DWG 146A0081 REV -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO BAY DOOR SURROUND STRUCTURE (FLOOR) HAS CORROSION ON FLOOR TO SIDEWALL SUPPORT AROUND NUTPLATES; BS 767-794; RBL 22. REMOVED AND REPLACED ACB FWD SHIELD BS767 TO BS794 IAW SRM 51-40-02 AND DWG 146A0081 REV -.