What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDE WAL SUPPORT AT BS 727A 827; RBL 22; WL 155. REMOVED AND REPLACED THE SIDEWALL SUPPORT IAW SRM 51-40-02, AND DWG 146A7500 REV B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON AFT CARGO BAY FLOOR TO SIDE WAL SUPPORT AT BS 727A 827; RBL 22; WL 155. REMOVED AND REPLACED THE SIDEWALL SUPPORT IAW SRM 51-40-02, AND DWG 146A7500 REV B.