What was found
CORROSION AFT CARGO BAY FLOOR SPLICE STRAP AROUND NUT PLATE HOLE BS 727D+6, RBL 11.5, WL 156. EVALUATED CORROSION OF FLOOR STRAP. FOUND TO BE OUT OF LIMITS, RECEIVED NEW STRAP AND APPLIED WHITE ENAMEL ALL IAW SRM 51-10-02, AMM 51-21-73-370-804, AND ACO 5360-E-16462.