CORRODED FLOORBEAM, BS 986, RBL 38-45, WL 208. INSTALLED A REPAIR IAW SRM 53-70-51-2R-6, ALTERNATIVE 3, FIG 204, SHEET 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORRODED FLOORBEAM, BS 986, RBL 38-45, WL 208. INSTALLED A REPAIR IAW SRM 53-70-51-2R-6, ALTERNATIVE 3, FIG 204, SHEET 1.