What was found
CRACKED STRINGER 7L, BS 296, LBL 41, WL 274. THE DAMAGE WAS REPAIRED IAW SRM 53-00-03-2R-1, REPAIR 1, AND EA 25-153-02976 WITH AN INSPECTION PROGRAM DEFINED IN 25-153-02976-INSP. HFEC INSPECTED AREA IAW NDTM PART 6, 51-00-00, PROCEDURE 23. CRACK NOTED. NO ALLOWABLE LIMIT FOUND FOR SPECIFIC LOCATION ON SRM 53-00-03-1A-1, ALLOWABLE DAMAGE 1, THEREFORE REPAIR IS NEEDED. REPAIR PROVIDED IAW SRM IS NOT APPLICABLE DUE TO LIMITATION GIVEN SRM 53-00-03-2R-1, REPAIR 1, PAR 1.C.(2) INITIAL STRINGER ON FWD AND AFT DIRECTIONS IS LESS THEN 20'. ENGINEERING WILL BE CONTACTED TO FURTHER REPAIR INSTRUCTIONS.