What was found
CRACKED FLOORBEAM, BS 540, RBL 2. REPLACED THE FLOORBEAM IAW SRM 51-10-02, ITEM 9, AND INSTALLED FASTENERS IAW SRM 51-40-02, AND DRAWING 143A5240, SHEET 14. MEASUREMENT OF CRACK: L 0.450 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FLOORBEAM, BS 540, RBL 2. REPLACED THE FLOORBEAM IAW SRM 51-10-02, ITEM 9, AND INSTALLED FASTENERS IAW SRM 51-40-02, AND DRAWING 143A5240, SHEET 14. MEASUREMENT OF CRACK: L 0.450 INCH.