What was found
FWD FLOOR PANEL 221DF LOWER SKIN IS CRACKED ON O/B EDGE COMMON TO DRAIN TROUGH STEP CUT. FWD FLOOR PANEL 221DF WITH LOWER SKIN CRACKED ON O/B EDGE COMMON TO DRAIN TROUGH STEP CUT WAS REPAIRED IAW SRM 53-00-50-2R-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD FLOOR PANEL 221DF LOWER SKIN IS CRACKED ON O/B EDGE COMMON TO DRAIN TROUGH STEP CUT. FWD FLOOR PANEL 221DF WITH LOWER SKIN CRACKED ON O/B EDGE COMMON TO DRAIN TROUGH STEP CUT WAS REPAIRED IAW SRM 53-00-50-2R-1.