What was found
CRACKED FLOOR SUPPORT BS 354, BL 0, WL 208. THE FLOOR SUPPORT WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-04-1A-1. REMOVED AND REPLACED IAW DWG 141A5400, REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FLOOR SUPPORT BS 354, BL 0, WL 208. THE FLOOR SUPPORT WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-04-1A-1. REMOVED AND REPLACED IAW DWG 141A5400, REV-.