What was found
CRACK LEADING EDGE RIB ACCESS PANEL 331B LOCATED LE HSS 188.94 AT LT HORIZONTAL STAB. REPLACED RIB ON LEADING EDGE ACCESS PANEL 331B LOCATED LE HSS 188.94 AT LT HORIZONTAL STAB IAW SRM 51-40-02-01-0G-0, SRM 51-10-02-0G-0, PARAGRAPH 9, & DWG 186A1001 SHEET 10, REV A. LENGTH OF CRACK: 0.269 INCH.