What was found
CRACK LEADING EDGE RIB LOC LE STA 95.96 AT LT HORIZONTAL STAB. REPLACED RIB AND FASTENERS LOC LE STA 95.96 AT LT HORIZONTAL STAB IAW SRM 51-40-02-0G-0, AND DWG 186A1303, SHEET 1, REV A, & DWG 186A1001, SHEET 19, REV-.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK LEADING EDGE RIB LOC LE STA 95.96 AT LT HORIZONTAL STAB. REPLACED RIB AND FASTENERS LOC LE STA 95.96 AT LT HORIZONTAL STAB IAW SRM 51-40-02-0G-0, AND DWG 186A1303, SHEET 1, REV A, & DWG 186A1001, SHEET 19, REV-.