What was found
CRACKED LEADING EDGE RIB, LE STA 151.75 AT RT HORIZONTAL STAB. REPLACED RIB AND FASTENERS IAW SRM 51-40-02, DWG 186A1001, SHEET 10, REV A .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED LEADING EDGE RIB, LE STA 151.75 AT RT HORIZONTAL STAB. REPLACED RIB AND FASTENERS IAW SRM 51-40-02, DWG 186A1001, SHEET 10, REV A .