What was found
CRACKED FLOOR CROSSBEAM, BS 540 BTWN BL 0 - RBL 24. REPLACED THE FLOOR CROSSBEAM IAW SRM 51-40-02-0G-0, SRM 51-10-02-0G-0, PARAGRAPH 9, AND DWG: 143A0060, SHEET 36, REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FLOOR CROSSBEAM, BS 540 BTWN BL 0 - RBL 24. REPLACED THE FLOOR CROSSBEAM IAW SRM 51-40-02-0G-0, SRM 51-10-02-0G-0, PARAGRAPH 9, AND DWG: 143A0060, SHEET 36, REV A.