What was found
DURING CRUISE, SMELLED AND SAW WHITE SMOKE COMING FROM F/O NR 3 WINDOW AREA. SHUT OFF F/O'S FWD AND SIDE WINDOW HEAT SWITCHES, SMOKE STOPPED. ALSO, FOUND GALLEY C/B TRIPPED ON P18-3 PANEL ROW B. CHECKED UNDER P5 OVERHEAD PANEL, CHECKED ALL RT SIDE WINDOWS AND HEAT CONNECTORS, REPOSITIONED SWITCH ON NR R5 WINDOW, RELAMPED RT SIDE C/B. INSPECTED LIGHT WITH CORRECT BULB, ACC OPS CK NORMAL IAW M/M.